This
atmospheric pressure sensor adopts an imported high-precision measuring unit.
The device has built-in high-precision temperature compensation, high
stability, low drift, and high repeatability. It can be easily fixed to the
wall by wall-mounted housing. Applicable to small weather stations and other
places that require atmospheric pressure monitoring and temperature
measurement.
Atmospheric
pressure sensor features:
1.10-30V wide DC voltage
supply atmospheric pressure sensor
2. atmospheric pressure sensor output can be RS485,4-20ma,0-5V, or 0-10V.
3. Atmospheric pressure and temperature are measured simultaneously
4. Wide range of 0-120Kpa air pressure range, can be applied to various
altitudes
Parameters
Power supply |
10~30V DC |
|
Measure range |
Air pressure |
0~120Kpa |
Temperature |
-40℃~80℃ |
|
Operating temperature |
-20℃~+60℃,0%RH~80%RH |
|
Accuracy |
Air pressure |
±0.15Kpa@25℃ 101Kpa |
Temperature |
±0.5℃ |
|
Long-term stability |
Air pressure |
-0.1Kpa/year |
Temperature |
≤0.1℃/year |
|
Output signal |
RS485/4~20mA/0~5V/0~10V |
|
Place of origin |
China |
Application
Barometric
pressure sensors are highly waterproof and use imported high-sensitivity
digital probe, which has a stable signal and high accuracy, applicable to
computer room monitoring system, security engineering, medical and health
monitoring, cold chain transportation, agricultural pastures, orchards, etc.
Atmospheric
pressure transmitter common problems and solutions
The
atmospheric pressure sensors cannot be connected to PLC or computer
possible reason:
1. The computer has multiple COM ports, and the selected port is incorrect.
2. The atmospheric pressure sensor address is incorrect, or there is a device
with a duplicate address (all the factory defaults to 1).
3. Baud rate, check mode, data bit, stop bit error.
4. The host polling interval and the waiting response time are too short and
need to be set to more than 200ms.
5. The 485 bus is disconnected, or the A and B lines are reversed.
6. If the number of the atmospheric pressure sensor is too large or the wiring
is too long, the power should be supplied nearby, add 485 enhancers, and
increase the resistance of 120Ω terminal.
7. The USB to 485 drivers is not installed or damaged.
8. Equipment damage.