• Analog Voltage 0-10v to RS485 Converter

For Downloads

Data Sheet – User Manual – Other Documents – Certificates

 

Setup Software

Testing Software

For Purchase

Call / WhatsApp / Telegram: +91 8148834200

For Technical Support

Call / WhatsApp / Telegram: +91 8148834211


Analog to rs485 converter using the standard Modbus-RTU protocol, address, baud rate can be set by the host computer software that can be articulated in the 485 bus. Products according to industry-standard design, manufacture, with over-voltage protection, over-current protection, anti-interference ability, high reliability.

Analog to RS485 Parameters

Power supply: DC 10~30V
Number of input channels: 1-way or 2-way optional
Acquire the Signal: 0-10v
Protocol: MODBUS-RTU
Input resistance: 4-20ma ≤200 ohms,0-5v/0-10v≥10K ohms
Power consumption: 0.4w
Signal output: RS485
AD conversion resolution: 10-bit or 12-bit optional
Storage environment: -20
~+60

 analog to rs485 converter

Analog to RS485 Converter Use

·        Intelligent building control, security, and engineering applications

·        Industrial sites, power distribution cabinets, and other places that require an RS485 output

·        Debugging and control of equipment operation

·        Medical machine monitoring

·        Sensor signal to restore the long-range transmission and signal

·        Industrial field data for a given actuator


analog to RS485 module


Wiring instructions

Types

Logo

Description

Remarks

Power input and communication

VCC

Power input positive

10~30V DC

GND

Power input ground

 

485A

485-A

Communication

485B

485-B                                   

Power output and signal input

VCC

Power output positive

Power output, module to equipment

GND

Power output ground

IN0

Analog 1 input

Common for two-wire, three-wire, and four-wire system

IN1

Analog 2 input

 

The conversion module only needs one end of the power supply to be able to work normally, and the other end of the power supply is prepared for the subsequent stage power supply. If the latter stage is not powered, it can be left floating.

When multiple 485 models are connected to the same bus, there are certain requirements for on-site wiring, please contact us for details.

 

Input signal wiring example

Wire system

VCC

GND

IN0

IN1

Two-wire system

Device power is positive

Air

Analog input 1

Analog input 2

Three-wire system

Equipment power ground

Analog input 1